Method of optimum intraoperative selection of the functions of automated measurement of thresholds of the implanted electric cardiac stiulators stimulation

A.N. Aleksandrov, I.V. Drozdov, A.Yu. Amiraslanov, S.Yu. Fedotov, L.G. Vinogradova, R.Z. Pashayev
Keywords: bradycardia, pacemaker, endocardial lead, threshold.
Medicinskij al'manah, 2017, issue 3, pages 119-122.

We developed the system of intraoperational measurement of ER signal based on deimplanted pacemakers.
This method was applied in 200 patients witch pacing indications. Intraoperationaly received data
allows to choose the optimal model of pacemaker depending on the type of autocapture function used.

1. Arribas F., Auricchio A., Boriani G., Statistics on the use of cardiac electronic
devices and electrophysiological procedures in 55 ESC countries: 2013 report from
the European Heart Rhythm Association (EHRA). Europace. 2014. Vol. 16 (4).
P. 533-540.
2. Kuck K.-H., Hindricks G., Padeletti L., Raatikainen P., Arnar D.O. The EHRA
White Вook 2016 (EHRA) URL: http://www.escardio.org/static_file/Escardio/
Subspecialty/EHRA/Publications/Documents/EHRA_White_book_2015 (дата
обращения: 7.12.2016).
3. Guerola M. Evoced R wave and lead polarization. New pacing parameters.
Arhives des maladies du coeur et des vaisseaux. 1998. T. 91. № 3. Vol. 18. P. 23-47.
4. Preston T.A., Bowers D.L. Report of a continuous threshold tracking system.
In Cardiac Pacing. Thalen. HJTh (ed). Van Gorcum, Assen. 1973. P. 295-299.
5. St. Jude Medical Company. Microny Clinical Report. Executive summary.
Pacesetter AB A-S-171 95 SOLNA. Sweden. Ordering. № 63 59 835 E502E. P. 1.
6. Udo E.O., van Hemel N.M., Zuithoff N.P.A., Dijk W.A., Hooijschuur C.A.M.,
Doevendans P.A., Moons K.G.M. Pacemaker follow-up: are the latest guidelines in
line with modern pacemaker practice? Europace. 2013. Vol. 15. P. 243-251.
7. Boriani G., Rusconi L., Biffi M., Pavia L., Sassara M., Malfitano D. et al. Role of
ventricular autocapture function in increasing longevity of DDDR pacemakers: a
prospective study. Europace. 2006. Vol. 8. P. 216-220.
8. Pegora D., Morandi F., Liccardo M., Pepi P., Orazi S. et al. Performance of a
Ventricular Automatic-capture Algorithm in Wide Clinical Setting. PACE. 2008. Dec.
Vol. 31. P. 1546-1553.
9. Benezet-Mazuecos J., Antonio Iglesias J., Manuel Rubio J., Cortеs M., de la
Cruz E. et al. Limitations of the AutoCapture™ Pacing System in patients with
cardiac stimulation devices. First published online. 2014. Vol. 16 (10). P. 1469-1475.
DOI: http://dx.doi.org/10.1093/europace/euu080.
10. Ribeiro A.L., Rincon L.G., Oliveira B.G., Vinha C.R., Melatto D., Torres A.A. et
al. Automatic adjustment of pacing output in the clinical setting. Am Heart J. 2004.
Vol. 147. P. 127-131.

A.N. Aleksandrov, I.V. Drozdov, A.Yu. Amiraslanov, S.Yu. Fedotov, L.G. Vinogradova, R.Z. Pashayev Method of optimum intraoperative selection of the functions of automated measurement of thresholds of the implanted electric cardiac stiulators stimulation. Medicinskij al'manah 2017; (3): 119–122, http://dx.doi.org/10.21145/2499-9954-2017-3-119-122