Highly sensitive troponin in diagnosing miocardial infarction: a real diagnostic value or overestimated capabilities?

L.Yu. Koroleva, N.A. Golitsyna, V.P. Nosov, M.V. Zlobin, Yu.N. Sobol, E.V. Gurvich
Keywords: highly sensitive troponins, troponins, myocardial infarction, ACS without ST elevation, literature review.
Medicinskij al'manah, 2017, issue 3, pages 165-168.

Early diagnosis of myocardial infarction (MI) is the milestone of prevention of early complications and mortality.

However, his diagnosis in the case of a combination of typical anginal syndrome without ST-segment

elevation in the ECG is a difficult task in the prehospital and early hospital stages of the management of

patients with acute coronary syndrome (ACS). The introduction of highly sensitive cardiac troponin

(hs-сTn) was able to increase the frequency of detection of MI up to 47% in patients with ACS without

ST-segment elevation. However, despite the obvious advantage of hs-Tn allowing cardiomyocyte necrosis

noted in the beginning of the disease, the cost of the high sensitivity of the method was the decrease in its

specificity, and the related difficulty of interpretation. The aim of this research is the analysis of the available

literature on the use of hs-сTn– the modern biomarkers of necrosis of cardiomyocytes.

1. Epidemiologiya neinfekcionnih zabolevanii. Materiali nauchno-prakticheskoi

konferencii / рod red. A.D. Botvinkina, F.I. Belyalova, L.E. Malcevoi. Irkutsk:

Izdatel'stvo IGMU, 2008. S. 15.

2. Vel'kovV.V. Visokochuvstvitel'noe izmerenie kardial'nih troponinov: test,

kotorii spasaet zhizni. Kliniko-laboratornii konsilium. Nauchno-prakticheskii

zhurnal. 2012. № 1 (41). S. 47-52.

3. Apple F.S. A new season for cardiac troponin assays: it’s time to keep a

scorecard. Clin Chem. 2009. № 55. Р. 1303-1306.

4. Jaffe A.S. Troponin - past, present and future. CurrProblCardiol. 2012.

№ 37 (6). Р. 209-228.

5. Lippi G., Montagnana M., Aloe R., Cervellin G. High sensitive troponin

immunoassays: navigating between the scylla and charybdis. AdvClinChem. 2012.

№ 58. Р. 1-29.

6. Ndrepepa G., Braun S., Mehilli J., et al. Prognostic value of sensitive troponin

T in patients with stable and unstable angina and undetectable conventional

troponin. Am Heart J. 2011. № 161. Р. 68-75.

7. Lankeit M., Friesen D., Aschoff J., et al. Highly sensitive troponin T assay in

normotensive patients with acute pulmonary embolism. Eur Heart J. 2010. № 31.

Р. 1836-1844.

8. Filusch A., Giannitsis E., Katus H.A., et al. High-sensitive troponin T: a novel

biomarker for prognosis and disease severity in patients with pulmonary arterial

hypertension. ClinSci (Lond). 2010. № 119. Р. 207-213.

9. de Lemos J.A., Drazner M.H., Omland T., et al. Association of troponin T

detected with a highly sensitive assay and cardiac structure and mortality risk in the

general population. JAMA. 2010. № 304. Р. 2503-2512.

10. de Filippi C.R., de Lemos J.A., Christenson R.H., et al. Association of serial

measures of cardiac troponin T using a sensitive assay with incident heart

failure and cardiovascular mortality in older adults. JAMA. 2010. № 304. Р.

2494-2502.

11. Saunders J.T., Mambi V., de Lemos J.A., et al. Cardiac troponin T

measured by a highly sensitive assay predicts coronary artery disease, heart

failure, and mortality in the Atherosclerosis Risk in Communities Study.

Circulation 2011. № 123. Р. 1367-1376.

12. White H.D. Pathobiology of troponin elevations. J AmCollCardiol. 2011. № 57.

Р. 2406-2408.

13. Keller T., Zeller T., Ojeda F., et al. Serial changes in highly sensitive troponin

I assay and early diagnosis of myocardial infarction. JAMA. 2011. № 306.

Р. 2684-2693.

14. Thygesen K., Mair I., Giannitsis E. et al. How to use high-sensitivity cardiac

troponins in acute cardiac care. EurHeart J. 2012. № 33 (18). Р. 2252-2257.

15. Al-Saleh A., Al Saleh Al Shalash A.et al. Performance of the high-sensitivity

troponin assay in diagnosing acute myocardial infarction: systematic review and

meta-analysis. CMAJ OPEN. № 2 (3). Р. 199-207.

16. Schreiber D.H., Agbo C., Wu A.H.B. et al. Short-term (90 min) diagnostic

performance for acute non-ST segment elevation myocardial infarction and 30-day

prognostic evaluation of a novel third-generation high sensitivity troponin I assay.

ClinBiochem. 2012. № 45. Р. 295-301.

17. Kelly A.M., Klim Sh. Does undetectable troponin J at presentation using a

contemporary sensitive assay rule out myocardial infarction? A cohortstudy.

EmergMed J. 2014. № 32. Р. 760-763.

18. Bandstein N., Ljung R., Johansson M., Holzmann M.J. Undetectable highsensitivity

cardiac troponin T level in the emergency department and risk of

myocardial infarction. J AmCollCardiol. 2014. № 63. Р. 2569-2578.

19. Carlton E.W., Cullen L., Than M. et al. A novel diagnostic protocol to identify

patients suitable for discharge after a single high-sensitivity troponin. Heart. 2015.

№ 101 (13). Р. 1041-1046.

20. Reichlin T., Cullen L., Parsonage W.A. et al. Two-hour-algorithm for triage

toward rule-out and rule-in of acute myocardial infarction using high-sensitivity

cardiac troponin. N Am J Med. 2015. № 128 (4). Р. 369-379.

21. Druey S., Wildi K., Twerenbold R. et al. Early rule-out and rule-in of

myocardial infarction using sensitive cardiac troponin I. Int J Cardiol. 2015. № 195.

Р. 163-170.

22. Marco R. et al. Task force for the management of acute coronary syndromes

in patients presenting without persistent ST-segment elevation of the European

Society of Cardiology (ESC) Eur Heart J. doi:10.1093/eurheartj/ehv320.

23. Mueller C. Biomarkers and acute coronary syndromes: an update. EurHeart J.

2014. № 35. Р. 552-556. 24. RubiniGimenez M., Hoeller R., Reichlin T., et al. Rapid rule out of acute

myocardial infarction using undetectable levels of high-sensitivity cardiac troponin.

Int J Cardiol. 2013. № 168. Р. 3896-3901.

25. Reichlin T., Twerenbold R., Wildi K., et al. Prospective validation of a 1-hour

algorithm to rule-out and rule-in acute myocardial infarction using a high-sensitivity

cardiac troponin T assay. CMAJ. 2015. № 187. Р. 243-252.

26. RubiniGimenez M., Twerenbold R., Jaeger C., et al. One-hour rule-in and

rule-out of acute myocardial infarction using high-sensitivity cardiac troponin I. Am

J Med. 2015. № 128. Р. 861-870.

27. Johannes T.N., et al. Diagnosis of myocardial infarction using a highsensitivity

troponin I 1-hour algorithm. JAMA Cardiol. 2016. № 1 (4). Р. 397-404.

28. Edward C. et al. Evaluation of high-sensitivity cardiac troponin I levels in patients

with suspected acute coronary syndrome. JAMA Cardiology. Publishedonline. 2016. June 1.

29. Mills N.L., Lee K.K., McAllister D.A., et al. Implications of lowering threshold

of plasma troponin concentration in diagnosis of myocardial infarction: cohort

study. BMJ. 2012. № 344. Р. 1533-1544.

30. Eggers K.M. Consequences of the implementation of a high-sensitivity

cardiac troponin assay at Swedish coronary care units. Presented at: European

Society of Cardiology Congress. London. 2015. September 1.